English |
Metric |
|
|
|
| Height (Erected Unit) |
52'5" / 629 in |
15.24 m |
| Width |
11" / 132 in |
3.65 m |
| Length |
57'5" / 689 in |
16.45 m |
| Height during transport |
13'8" / 164 in |
4.16 m |
| Weight including mounting platform |
38000 lbs |
17,272 kg |
| Caloric Output - gas (at 8,500 BTU/lb fuel
heat value) |
50 MMBTU/hr |
|
| Electric output (external diesel
generator) |
2000 kw |
2000 kw |
| Output voltage |
480 volts 3-phase |
480 volts 3-phase |
| Line synchronization |
Automatic or Manual |
Automatic or Manual |
| Startup power demand |
250kw max |
250kw max |
| Startup time cold ->full output |
15 mins |
15 mins |
| Startup time cold -> self sustaining
power |
7 mins |
7 mins |
| Service interval est. |
2 hr/day |
2 hr/day |
| Lifetime of main components |
20 years |
20 years |
| Water demand (dep. fuel contitions) |
35 ft3/day
±50% |
1 m3/day
±50% |
| Lime powder demand |
330 lbs |
150 kg/day |
| Reactor pressure at outlet flange |
2 in h2o
negative |
5 cm in h2o negative |
| Gas outlet pressure on systems manifold |
0-15 psi |
0-1 ATM |
| Fuel gas caloric value (average) |
140 BTU/ft3 |
|
| Fuel gas temperature at manifold |
Ambient |
Ambient |
| Fuel gas flow, nominal power |
4,857 ft3/sec |
4,857 cfm |
| Fuel Gas outlet manifold connection |
8" Schedule 40 pipe |
8" Schedule 40 pipe |
| Fuel Demand (MSW dep. on water content) |
40 dry -100wet tons/day |
40 dry -100wet tons/da |
|
|
|